Construction Details (Typical)

Base of Wall

Fig 14.1 Hebel PowerBlock work on Stiffened Raft Slab Edge Foundation (elevation)

Fig 14.2 Hebel PowerBlock work showing infill block to slab rebate (elevation)

Fig 14.3 Internal Load Bearing Hebel PowerBlock  work on stiffened raft slab foundation (elevation).

Fig 14.4 Concrete PowerBlock Sub-Floor Detail (elevation)

Fig 14.5 Roof Top to Plate Fixing to Hebel Wall – Strap (elevation) – for vaulted/cathedral roofs.

Fig 14.6 Roof Top to Plate Fixing to Hebel Wall – Strap (elevation) – for typical trussed roof

Fig 14.7  Strap Fixing to Hebel Walls (isometric – typical trussed roof)

 

Fig 14.8  Double Brick Sub-Floor Detail (elevation)

Fig 14.9 Ring Beam Internal Non-Loadbearing Wall (elevation)

Top of Wall

Fig 14.10 Internal Hebel Load Bearing Wall and Timber Floor Frame Junction (elevation)

 

Fig 14.11 Truss Spanning Over Non-Load Bearing Hebel Walls (elevation)

 

Fig 14.12 Timber Truss/Joist Fixed to Hebel Walls (elevation)

 

Fig 14.13  Tiled Roof Eve and Hebel Wall Junction (elevation)

Fig 14.14  Vaulted Ceiling & Roof Top Plate Fixing To Hebel  Wall (elevation)

Wall Junctions

Fig 14.15  External Wall and Internal Partition Wall Junction  (plan)

Fig 14.16  External Corner with Control Joint (plan)

Control Joints

Fig 14.17  Control Joint detail (elevation)

Fig 14.18 Typical Bond Beam Control Joint – elevation

Fig 14.19 Typical Control Joint – plan

Fig 14.20 Typical Ring Beam Control Joint – elevation

Fig 14.21 Hebel PowerBlock work Typical Movement Joint Detail (elevation)

Fig 14.22 Hebel PowerBlock work Typical Movement Joint Detail (plan)

Fig 14.23 Built-in Column Detail (plan)

Fig 14.24 Built-in Column Detail (elevation)

Floors

Fig 14.25 Non-Load Bearing Hebel PowerBlock Wall and Hebel Floor Panel Detail (elevation)

Fig 14.26 Loadbearing Hebel PowerBlock Wall and Floor Panel Junction Detail (elevation)

Fig 14.27  Loadbearing Hebel PowerBlock Wall and Timber Floor Frame Junction Detail (elevation)

Fig 14.28 Timber Floor Support Detail (elevation)

Fig 14.29  Hebel Flooring Panels using Ring Anchor Construction on Load Bearing Interior Wall (elevation)

Fig 14.30 Ceiling Support Detail A (elevation)

Fig 14.31  Ceiling Support Detail B (isometric)

NOTE: Refer to section 7.12 of the Hebel Technical Manual for the full set of Details on the Floor Panel System.

Balcony and Deck

Fig 14.32  Balcony Detail (elevation)

Fig 14.33  Balcony Detail (elevation)

Fig 14.34  Deck Connection Detail (side elevation)

Fig 14.35 Deck Connection Detail (front elevation)

Stairs

Fig 14.36  Stairwell (isometric)

Fig 14.37  Stair Tread Set-Out (isometric)

Fig 14.38 200mm wide x 50mm thick Hebel PowerBlocks adhered to walls on their ends to provide support for treads (isometric)

Openings

Fig 14.39 Steel Door Frame (Internal or External) to Hebel Wall Fixing (plan)

Fig 14.40  Steel Door Frame (Internal or External) to Hebel Wall Fixing (plan)

Fig 14.41  Timber Door Frame (External) to Hebel Wall Fixing (plan)

Fig 14.42  Timber Door Frame (Internal) to Hebel Wall Fixing (plan)

Fig 14.43  Aluminium Window Frame – Window Sill Detail (elevation)

Fig 14.44 Aluminium Window Frame – Window Jamb Detail (elevation)

Fig 14.45  Aluminium Window Frame – Window Head Detail (elevation)

Fig 14.46 Lintel Installation

 (a) Elevation                                                                                                                                                  

(b) Section

find out more

 

This entry was posted in CSR Hebel Power Panels and Blocks and tagged , , , , , , , , , , , , , , . Bookmark the permalink.